Connect machines
Let injection, blow moulding and other machines send their shot counts and status, so runs count themselves and stops are logged.
A connected machine tells the ERP how many cycles it ran, how long each took, and whether it is running, idle or in alarm. You don't type the count at the end of a shift. The run's quantity goes up by itself, and every stop is logged with its time and alarm.
1. Set up the machine
Go to Manufacturing → Work centres and click Machine next to the machine. Under Machine details fill in:
- Type, Make / model and Capacity, for example Injection moulding, Haitian MA 3600, 350 T.
- Parts per cycle: the cavities. It's only used when the product has no Cavities set and the machine doesn't send them.
- Standard cycle (s): the cycle time the machine should run at. Today's average is shown next to it.
2. Make a key
Click Make key and copy it. It's shown only once. Give it, with the Send to address, to whoever sets up the machine or the gateway PC.
New key replaces the old one, and the machine stops sending until it has the new key. Remove key disconnects the machine.
3. Connect the machine
The ERP can't reach into your factory network, so the machines send to it. There are two ways to do that:
- Gateway PC (recommended). Click Gateway script (Python) and run it on a PC or Raspberry Pi on the machines' network. It reads machines over OPC UA / Euromap 77 (most injection machines from about 2018) or Modbus TCP (PLCs and shot counters). When the internet is down it keeps readings and sends them later. Run
python erp_machine_gateway.py --init, fill in the address and each machine's key ingateway.json, then start it. - Older machines. Fit a simple shot counter that counts the mould-open signal and speaks Modbus, and add it to the gateway the same way.
Press Send test to check the page. A test reading shows in Latest readings but doesn't change counts or status.
4. Which run gets the count
The machine counts for, in this order:
- the run named in the message;
- the run you pick under Counting for;
- the run whose operation is started on this work centre;
- an in-progress run whose Facility is the machine's name or code.
Only runs In progress are counted. With no run, readings are still logged.
Good parts are the shots × cavities (from the product, the message or Parts per cycle) less rejects. When you Complete the run, Actual quantity starts at the machine's count. Change it if the count on the floor is different.
5. Stops
When a machine reports idle, setup, alarm or down, a stop starts. It ends when the machine reports running again. Stops on the machine page shows each one with its alarm and minutes, and Stopped shows today's total.
6. Machine board and OEE
Manufacturing → Machine board shows every connected machine on one screen and refreshes every 30 seconds. For each machine you see:
- its status;
- the run with a progress bar;
- today's shots, good parts, rejects and minutes stopped;
- the last cycle against the standard (red when slower);
- its mould and how close it is to service.
OEE is counted from the first reading today:
- Availability: time running out of the time since the first reading, up to the work centre's Hours / day.
- Performance: standard cycle × shots out of the running time. It needs a Standard cycle.
- Quality: good parts out of good + rejects.
OEE = availability × performance × quality. It shows green from 85%, amber from 60%, and red below that.
7. Moulds & dies
Manufacturing → Moulds & dies lists every mould, die or press tool with its Service every (shots) and Life (shots).
- Put the tool On machine and that machine's shots are added to it. One tool can be on a machine at a time.
- If it isn't on a machine, the tool counts shots from runs of any product whose Mould no. is the tool's code.
- The tool's Cavities are used before the product's.
- It turns Soon at 90% of the interval and Due at 100%.
- After servicing, click Serviced, note the work done and who did it, and click Record service. The service is logged with the shot count, and the count since service starts again. History shows every service.
8. Alerts
Alerts are rules, not AI. They go to the bell (the owner and Production Managers) and on WhatsApp to the numbers set under Alerts on the machine board. You get an alert when:
- a machine reports alarm or down, once per stop;
- a machine is idle or in setup longer than the minutes you set;
- a running machine sends nothing for the minutes you set (the machine or its gateway is off the network);
- the last cycle times average more than the set % over the standard, at most every 2 hours;
- a mould is due for service, once per interval.
Set any number to 0 to switch that rule off.
For WhatsApp, create and get approval for a template named machine_alert with two variables: the machine, then what happened. Until it's approved, alerts go to the bell only.
By industry
The words and choices follow your company's industry:
| Industry | Counts | Machine types offered | Tooling register |
|---|---|---|---|
| Plastics & moulding | shots | injection, blow, extrusion, thermoforming | Moulds, matched by the product's Mould no. |
| Casting | shots | die casting, gravity/LPDC, furnace, CNC | Dies & patterns, matched by Pattern no. |
| Sheet metal | strokes | press, press brake, laser, punching, welding | Press tools & dies |
| Forging | strokes | forging press, hammer, press, furnace | Dies |
| Auto components | cycles | press, CNC, VMC, injection, die casting | Tools, dies & moulds |
| Medical equipment | shots | injection, extrusion, CNC, assembly | Moulds |
| Footwear | cycles | injection, press, sewing | Sole moulds & cutting dies |
| Ceramics | strokes | press, kiln | Dies |
| Packaging | impressions | printing, die cutting, extrusion, slitting | Cutting dies & cylinders |
| Corrugated box | sheets | corrugator, printing, die cutting | Cutting dies & plates |
| Pharma manufacturing | strokes | tablet press, mixer, filling | Punches & dies |
| Tool room, cables, steel service, solar, furniture, textile, fashion, jewellery, chemicals, paints, food, agri inputs, ayurveda | cycles (metres for cables, cuts for steel) | that industry's machines | none: Moulds & dies is hidden |
A company without an industry gets every machine type and Moulds & dies. A machine type saved earlier stays selectable if the industry changes.
For the person setting up the connection
POST to the Send to address with the header Authorization: Bearer <key> and a JSON body:
| Field | Meaning |
|---|---|
counter |
The machine's own shot counter. The first value is the starting point; a lower value means it was reset. |
shots |
Cycles since the last message, if there is no counter. |
good, rejects |
Parts. Without good, good = shots × cavities − rejects. |
cavities |
Parts per shot, if the mould's differs from the product. |
cycle_time |
Seconds. |
status |
running, idle, setup, alarm, down or off. |
alarm |
Alarm code or text. |
order |
Run number or target batch number, to count for a particular run. |
at |
Time of the reading (ISO 8601). Defaults to when it arrives. |
data |
Anything else, for example {"melt_temp": 228}. |
test |
true to check the connection without changing anything. |
To send readings kept while offline, put up to 500 of them in one message as {"readings": [ ... ]}, each with its own at.